Products

  • Chrome-Plated Quick Response Horizontal Sidewall Fire Sprinkler Head

    Chrome-Plated Quick Response Horizontal Sidewall Fire Sprinkler Head

    Parameters and Functions Model & Sprinkler I.D. No.  NX021 Style Horizontal Sidewall Response & Bulb Nominal Dia. Standard Response, Ø5 mm Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)∕80 (metric) Max. Working Pressure 175 psig∕1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig∕0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated White ...
  • Chrome-Plated Brass Sidewall Fire Sprinkler for Corrosion Resistance

    Chrome-Plated Brass Sidewall Fire Sprinkler for Corrosion Resistance

    Parameters and Functions Model & Sprinkler I.D. No.  NX021 Style Horizontal Sidewall Response & Bulb Nominal Dia. Standard Response, Ø5 mm Thread Size [Optional] NPT1/2 or R1/2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 1 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated Whit...
  • Horizontal Sidewall Fire Sprinkler for Efficient Space Protection

    Horizontal Sidewall Fire Sprinkler for Efficient Space Protection

    Parameters and Functions Model & Sprinkler I.D. No. NX022 Style Horizontal Sidewall Response & Bulb Nominal Dia. Quick Response, Ø3 mm Thread Size [Optional] NPT1/2 or R1/2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 1 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated White Co...
  • Upright Style Fire Sprinklers for Warehouses and Industrial Facilities

    Upright Style Fire Sprinklers for Warehouses and Industrial Facilities

    Parameters and Functions Model & Sprinkler I.D. No. NX024 Style Upright Bulb Nominal Dia. & Response Ø3mm, Quick Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated E...
  • The Standard Pendant Sprinkler for Effective Fire Suppression Systems

    The Standard Pendant Sprinkler for Effective Fire Suppression Systems

    Parameters and Functions Model & Sprinkler I.D. No. NX025 Style Pendent Bulb Nominal Dia. & Response Ø5mm,Standard Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated ...
  • Upright Sprinkler Heads – Professional Grade Fire Suppression Equipment

    Upright Sprinkler Heads – Professional Grade Fire Suppression Equipment

    Parameters and Functions Model & Sprinkler I.D. No. NX023 Style Upright Bulb Nominal Dia. & Response Ø5mm, Standard Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated ...
  • Standard Pendant Sprinklers for Automatic Fire Suppression Systems

    Standard Pendant Sprinklers for Automatic Fire Suppression Systems

    Parameters and Functions Model & Sprinkler I.D. No. NX026 Style Pendent Bulb Nominal Dia. & Response Ø3mm, Quick Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated E...
  • Commercial Upright Sprinkler with Quick Response Glass Bulb & Corrosion-Resistant Finish

    Commercial Upright Sprinkler with Quick Response Glass Bulb & Corrosion-Resistant Finish

    Parameters and Functions Model & Sprinkler I.D. No. NX024 Style Upright Bulb Nominal Dia. & Response Ø3mm, Quick Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated E...
  • Pendent Fire Sprinkler Head for Commercial Buildings

    Pendent Fire Sprinkler Head for Commercial Buildings

    Parameters and Functions Model & Sprinkler I.D. No. NX025 Style Pendent Bulb Nominal Dia. & Response Ø5mm,Standard Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated ...
  • Pendent Fire Sprinkler with Glass Bulb Technology

    Pendent Fire Sprinkler with Glass Bulb Technology

    Parameters and Functions Model & Sprinkler I.D. No. NX026 Style Pendent Bulb Nominal Dia. & Response Ø3mm, Quick Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color Coated E...
  • Upright Fire Sprinkler For Industrial And Storage Facilities

    Upright Fire Sprinkler For Industrial And Storage Facilities

      Parameters and Functions Model & Sprinkler I.D. No. NX023 Style Upright Bulb Nominal Dia. & Response Ø5mm, Standard Response Thread Size [Optional] NPT1/2 or R12 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass orChrome Plated orWhite Color ...
  • Sidewall Sprinkler Head For Wall Mounted Fire Protection

    Sidewall Sprinkler Head For Wall Mounted Fire Protection

    Parameters and Functions Model & Sprinkler I.D. No.  NX021 Style Horizontal Sidewall Response & Bulb Nominal Dia. Standard Response, Ø5 mm Thread Size [Optional] NPT1/2 or R1/2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 1 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated Whit...