Sticking to your belief of Creating solutions of high quality and generating buddies with people from all around the world, we always put the fascination of customers to start with for Brass Sprinkler, Automatic Fire Extinguisher Sprinkler Valvece, Fire Sprinkler System Companies, Our final target is To consider the most effective, To be the Best. Please experience cost-free to call with us if you have any prerequisites.
Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong Detail:

Size(mm) Temperature Rating(℃/°F) Color
A 3.8 57℃ / 135°F orange
B 2.02 68℃ / 155°F red
C <4.5 79℃ / 175°F yellow
D 5±0.1 93℃ / 200°F green
d1 5.1±0.2 141℃ / 286°F blue
d2 5.1±0.3
L 19.8±0.5
l1 16±0.4
l2 15.8±0.4
Glass bulb load(N) Average Cursh load(X) 4000
lower Tolerance Limit(TL) ≥2000
Maximum clamping torque 8.0 N·cm
Response time index(m*s)0.5 80<RTI≤350

 

Although it is smaller, each product is subject to strict factory inspection before leaving the factory, including appearance, size, static action temperature and crushing load test.
During the static action temperature test, the test ambient temperature is (20 ± 5) ℃, and the test is carried out in liquid bath. Water bath (distilled water is preferred) shall be adopted for glass bulbs with nominal operating temperature not higher than 79 ℃, and oil bath (oil products suitable for nominal operating temperature) shall be adopted for glass bulbs with nominal operating temperature higher than 79 ℃. The temperature of the test liquid bath shall be uniform, the temperature deviation in the test area shall not exceed 0.5 ℃, and the temperature measurement accuracy shall not be less than ± 0.1 ℃.
Place the glass bulb sample vertically in the liquid bath. The distance between the center of the glass bulb and the liquid level is not less than (40 ± 5) mm. Raise the temperature from room temperature to (20 ± 2) ℃ lower than the nominal operating temperature at a heating rate of not more than 20 ℃ / min. after holding for 10 minutes, raise the temperature at a rate of 0.4 ℃ / min ~ 0.6 ℃ / min until all the samples are broken. Record the operating temperature of each sample, Judge whether the test results exceed the following temperature range:
X ±(0.035X + 0.62)
X — Nominal operating temperature, unit: Celsius (℃).


Product detail pictures:

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures

Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong detail pictures


Related Product Guide:

We're committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Chinese wholesale 5mm 57℃ Bulb - Standard response sprinkler bulbs (short type) – Zhurong , The product will supply to all over the world, such as: Florida, Guinea, Congo, We have sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By lucia from Indonesia - 2018.12.10 19:03
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Karl from Mauritania - 2017.01.28 18:53
    Write your message here and send it to us