Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Always customer-oriented, and it's our ultimate target to be not only the most reliable, trustable and honest supplier, but also the partner for our customers for Sprinkler Fire Fighting System, Zst Fire Nozzle Type, Acid-washed, We cordially welcome customers from at home and abroad to join us and cooperate with us to enjoy a better future.
Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong Detail:

kjhgoiuhjkl

Size(mm) Temperature Rating (℃/°F) Color
A 2.4 68℃ / 155°F red
B 1.5 79℃ / 175°F yellow
C <4.2 93℃ / 200°F green
D 3±0.1 141℃ / 286°F blue
d1 3.5±0.4
d2 3.5±0.3
L 23±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 3600
lower Tolerance Limit(TL) ≥1600
aximum clamping torque 6.5 N·cm
Response time index(m*s)0.5 RTI≤50

 

The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response will be faster, RTI ≤ 50, where RTI is a coefficient measured under standard conditions to measure the sensitivity of sprinkler bulb. Expressions:RTI= τ u ½

Where: RTI – response time coefficient, unit (m * s) ½;
τ- Response time constant, in s;
u – gas flow rate, unit: m / s
The quality of the sprinkler bulb fully complies with the Chinese national standard GB18428-2010. The diameter of the sprinkler bulb is 3mm, and the deviation from the nominal diameter will not exceed ± 0.1mm; Its length is 23mm and the deviation from the nominal length will not exceed 0.5mm.
The average crushing load of the sprinkler bulb is 3600n. During the test, the sprinkler bulb will be fixed between the supporting elements in an appropriate way, and the supporting elements are made of steel. The Rockwell hardness is (44 ± 6) HRC, which meets the corresponding service requirements. Then, apply a uniform load along the axis of the sprinkler bulb until the sprinkler bulb bursts, and the rate of load increase is (250 ± 25) N / s. The maximum deviation of the equipment used to measure the crushing load shall not exceed ± 1% of the measured value. Use multiple groups of measured data to calculate the average value and standard deviation of the crushing load and judge whether the results meet the specified standards.


Product detail pictures:

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: Jordan, Lahore, Swiss, We welcome you to visit our company & factory and our showroom displays various products that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to provide you with the best services. If you need more information, please do not hesitate to contact us via E-mail, fax or telephone.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Constance from Mumbai - 2018.12.14 15:26
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Ina from UK - 2018.05.13 17:00
    Write your message here and send it to us