Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are experienced manufacturer. Wining the majority of the crucial certifications of its market for 3mm 141℃ Bulb, Wobbler Irrigation Sprinkler, Pendent Spray Nozzle, Striving hard to attain continual success based on quality, reliability, integrity, and complete understanding of market dynamics.
Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong Detail:

kjhgoiuhjkl

Size(mm) Temperature Rating (℃/°F) Color
A 2.4 68℃ / 155°F red
B 1.5 79℃ / 175°F yellow
C <4.2 93℃ / 200°F green
D 3±0.1 141℃ / 286°F blue
d1 3.5±0.4
d2 3.5±0.3
L 23±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 3600
lower Tolerance Limit(TL) ≥1600
aximum clamping torque 6.5 N·cm
Response time index(m*s)0.5 RTI≤50

 

The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response will be faster, RTI ≤ 50, where RTI is a coefficient measured under standard conditions to measure the sensitivity of sprinkler bulb. Expressions:RTI= τ u ½

Where: RTI – response time coefficient, unit (m * s) ½;
τ- Response time constant, in s;
u – gas flow rate, unit: m / s
The quality of the sprinkler bulb fully complies with the Chinese national standard GB18428-2010. The diameter of the sprinkler bulb is 3mm, and the deviation from the nominal diameter will not exceed ± 0.1mm; Its length is 23mm and the deviation from the nominal length will not exceed 0.5mm.
The average crushing load of the sprinkler bulb is 3600n. During the test, the sprinkler bulb will be fixed between the supporting elements in an appropriate way, and the supporting elements are made of steel. The Rockwell hardness is (44 ± 6) HRC, which meets the corresponding service requirements. Then, apply a uniform load along the axis of the sprinkler bulb until the sprinkler bulb bursts, and the rate of load increase is (250 ± 25) N / s. The maximum deviation of the equipment used to measure the crushing load shall not exceed ± 1% of the measured value. Use multiple groups of measured data to calculate the average value and standard deviation of the crushing load and judge whether the results meet the specified standards.


Product detail pictures:

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

The really abundant projects administration experiences and just one to one particular provider model make the substantial importance of organization communication and our easy understanding of your expectations for Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: Angola, Ethiopia, New Delhi, Nowadays our merchandise sell all over the domestic and abroad thanks for the regular and new customers support. We supply high quality product and competitive price, welcome the regular and new customers cooperate with us!
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Denise from Netherlands - 2017.06.16 18:23
    The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Dominic from Iran - 2018.11.02 11:11
    Write your message here and send it to us