Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

No matter new shopper or old customer, We believe in very long expression and dependable relationship for Fogger Micro Sprinkler, Sprinklerbirnen, Automatic Fire Sprinklers Inc, To benefit from our strong OEM/ODM capabilities and considerate services, please contact us today. We will sincerely create and share success with all clients.
Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong Detail:

Size(mm) Temperature Rating (℃/°F) Color
A 2.4 68℃ / 155°F red
B 1.5 79℃ / 175°F yellow
C <4.2 93℃ / 200°F green
D 3±0.1 141℃ / 286°F blue
d1 3.5±0.4
d2 3.5±0.3
L 23±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 3600
lower Tolerance Limit(TL) ≥1600
aximum clamping torque 6.5 N·cm
Response time index(m*s)0.5 RTI≤50

kjhgoiuhjkl

The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response will be faster, RTI ≤ 50, where RTI is a coefficient measured under standard conditions to measure the sensitivity of sprinkler bulb. Expressions:RTI= τ u ½

Where: RTI – response time coefficient, unit (m * s) ½;
τ- Response time constant, in S;
u – gas flow rate, unit: M / s
The quality of the sprinkler bulb fully complies with the Chinese national standard GB18428-2010. The diameter of the sprinkler bulb is 3mm, and the deviation from the nominal diameter will not exceed ± 0.1mm; Its length is 23mm and the deviation from the nominal length will not exceed 0.5mm.
The average crushing load of the sprinkler bulb is 3600n. During the test, the sprinkler bulb will be fixed between the supporting elements in an appropriate way, and the supporting elements are made of steel. The Rockwell hardness is (44 ± 6) HRC, which meets the corresponding service requirements. Then, apply a uniform load along the axis of the sprinkler bulb until the sprinkler bulb bursts, and the rate of load increase is (250 ± 25) n / s. The maximum deviation of the equipment used to measure the crushing load shall not exceed ± 1% of the measured value. Use multiple groups of measured data to calculate the average value and standard deviation of the crushing load and judge whether the results meet the specified standards.


Product detail pictures:

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

We hold strengthening and perfecting our items and repair. At the same time, we get the job done actively to do research and progress for Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: Greece, belarus, Zambia, Today, We are with great passion and sincerity to further fulfill our global customers' needs with good quality and design innovation. We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Constance from Slovakia - 2018.09.21 11:44
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By mary rash from San Diego - 2017.05.02 18:28
    Write your message here and send it to us