Model ESFR-242/74℃ P ESFR-202/68℃ P ESFR-202/68℃ U ESFR-202/74℃ P ESFR-202/74℃ U ESFR-242/74℃ U ESFR-323/74℃ P ESFR-323/74℃ U ESFR-363/74℃ P ESFR-363/74℃ U Mounting Pendent Upright Pendent Upright Pendent Upright Pendent Upright Pendent Upright Flow Characteristics 202 202 242 323 363 Thread Size R₂ 3/4 R₂ 1 Nominal action temperature 68℃ 74℃ Nominal Working Pressure 1.2MPa Factory test pressure 3.4MPa Background – History In the 1980s, early suppression, fast response (ESFR... -
Good Quality Dry Pendent Sprinkler - ZSTW B water mist sprinkler – Zhurong
Model ZSTW B-15 ZSTW B-20 ZSTW B-25 Flow Characteristics 15 20 25 Thread Size R₂ 1/2 Nominal Working Pressure 0.35MPa Injection Angle(°) 120 Water mist sprinkler refers to the sprinkler that decomposes the water flow into water droplets less than 1mm under a certain water pressure. Water mist sprinkler is an important component of its system. It works under a certain water pressure, decomposes the flowing water into small droplets and sprays them into fog shape. It sprays un... -
Factory For Ffire Glass Bulb Sprinkler - sprinkler bulbs customized ( length, logo, temperature ) – Zhurong
Size(mm) Temperature Rating(℃/°F) Color A 3.8 57℃ / 135°F orange B 2.02 68℃ / 155°F red C <4.5 79℃ / 175°F yellow D 5±0.1 93℃ / 200°F green d1 5.3±0.2 141℃ / 286°F blue d2 5.3±0.3 L 24.5±0.5 l1 20±0.4 l2 19.8±0.4 Glass bulb load(N) Average Cursh load(X) 4000 lower Tolerance Limit(TL) ≥2000 Maximum clamping torque 8.0 N·cm Response time index(m*s)0.5 80<RTI≤350 As a professional sprinkler bulb manufacturer, MH has its own special R &... -
2022 New Style Upright Sprinklers - ZSTM B water curtain sprinkler – Zhurong
Model ZSTM B-15 ZSTM B-20 ZSTM B-25 Flow Characteristics 15 20 25 Thread Size R₂ 1/2 Nominal Working Pressure 0.1MPa Injection Angle(°) 120 The water curtain sprinkler is a spraying device fixed in the pipeline of the water curtain system, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Water curtain sprinkler is mainly used for fire-proof partition, fire-proof zoning and local cooling. It ... -
OEM/ODM Factory Sprinkler Plate - ZSTM B water curtain sprinkler – Zhurong
Model ZSTM B-15 ZSTM B-20 ZSTM B-25 Flow Characteristics 15 20 25 Thread Size R₂ 1/2 Nominal Working Pressure 0.1MPa Injection Angle(°) 120 The water curtain sprinkler is a spraying device fixed in the pipeline of the water curtain system, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Water curtain sprinkler is mainly used for fire-proof partition, fire-proof zoning and local cooling. It ... -
Fire Sprinkle ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong
Fire Sprinkler Type Side wall Material Brass Nominal diameter(mm) DN15 or DN20 K factor 5.6(80) OR 8.0(115) Rated Working Pressure 1.2MPa Testing pressure 3.0MPa holding pressure for 3min Sprinkler Bulb Fast response Temperature rating 93℃(200℉) What is a sidewall sprinkler head? Sidewall fire sprinklers install along walls or beneath beams where ceiling piping is unavailable, or where aesthetic concerns or obstructions weigh against the use of other sprinkler types.... -
Lowest Price for Types Of Fire Sprinklers - ZSTM B water curtain sprinkler – Zhurong
Model ZSTM B-15 ZSTM B-20 ZSTM B-25 Flow Characteristics 15 20 25 Thread Size R₂ 1/2 Nominal Working Pressure 0.1MPa Injection Angle(°) 120 The water curtain sprinkler is a spraying device fixed in the pipeline of the water curtain system, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Water curtain sprinkler is mainly used for fire-proof partition, fire-proof zoning and local cooling. It ... -
Massive Selection for Drencher Sprinkler Head - ZSTM B water curtain sprinkler – Zhurong
Model ZSTM B-15 ZSTM B-20 ZSTM B-25 Flow Characteristics 15 20 25 Thread Size R₂ 1/2 Nominal Working Pressure 0.1MPa Injection Angle(°) 120 The water curtain sprinkler is a spraying device fixed in the pipeline of the water curtain system, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Water curtain sprinkler is mainly used for fire-proof partition, fire-proof zoning and local cooling. It ... -
Professional China 3mm 68℃ Bulb - 3mm Fast response sprinkler bulbs – Zhurong
Size(mm) Temperature Rating (℃/°F) Color A 2.4 68℃ / 155°F red B 1.5 79℃ / 175°F yellow C <4.2 93℃ / 200°F green D 3±0.1 141℃ / 286°F blue d1 3.5±0.4 d2 3.5±0.3 L 23±0.5 l1 20±0.4 l2 19.8±0.4 Glass bulb load(N) Average Cursh load(X) 3600 lower Tolerance Limit(TL) ≥1600 aximum clamping torque 6.5 N·cm Response time index(m*s)0.5 RTI≤50 The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response... -
Fire Extinguishing Plant Equipment ZSTX 15-68℃ Pendent Chrome plated Fire sprinkler heads – Zhurong
Fire Sprinkler Type Pendent Material Brass Nominal diameter(mm) DN15 or DN20 K factor 5.6(80) OR 8.0(115) Rated Working Pressure 1.2MPa Testing pressure 3.0MPa holding pressure for 3min Sprinkler Bulb Standard response Temperature rating 68℃(155℉) What is a pendent sprinkler head? A pendent (sometimes spelled “pendant”) fire sprinkler hangs from above-ceiling pipes and distributes water in a domed or conical pattern using a convex deflector. Unlike conce... -
Fire Fighting Eqiupment ZSTX 15-68℃ Pendent Chrome plated Fire sprinkler heads – Zhurong
Fire Sprinkler Type Pendent Material Brass Nominal diameter(mm) DN15 or DN20 K factor 5.6(80) OR 8.0(115) Rated Working Pressure 1.2MPa Testing pressure 3.0MPa holding pressure for 3min Sprinkler Bulb Standard response Temperature rating 68℃(155℉) What is a pendent sprinkler head? A pendent (sometimes spelled “pendant”) fire sprinkler hangs from above-ceiling pipes and distributes water in a domed or conical pattern using a convex deflector. Unlike conce... -
Personlized Products Drencher System - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong
Model ESFR-242/74℃ P ESFR-202/68℃ P ESFR-202/68℃ U ESFR-202/74℃ P ESFR-202/74℃ U ESFR-242/74℃ U ESFR-323/74℃ P ESFR-323/74℃ U ESFR-363/74℃ P ESFR-363/74℃ U Mounting Pendent Upright Pendent Upright Pendent Upright Pendent Upright Pendent Upright Flow Characteristics 202 202 242 323 363 Thread Size R₂ 3/4 R₂ 1 Nominal action temperature 68℃ 74℃ Nominal Working Pressure 1.2MPa Factory test pressure 3.4MPa Background – History In the 1980s, early suppression, fast response (ESFR...