While using the Client-Oriented company philosophy, a demanding high-quality management method, innovative producing products and also a sturdy R&D workforce, we always deliver premium quality merchandise, superb solutions and aggressive selling prices for Thermo Bulbs, Zst Types Glass Bulb Fire Sprinkler, Fire Sprinkler Systems, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us.
Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong Detail:

Model ESFR-202/68℃ P ESFR-202/68℃ U ESFR-202/74℃ P ESFR-202/74℃ U ESFR-242/74℃ P ESFR-242/74℃ U ESFR-323/74℃ P ESFR-323/74℃ U ESFR-363/74℃ P ESFR-363/74℃ U
Mounting Pendent Upright Pendent Upright Pendent Upright Pendent Upright Pendent Upright
Flow Characteristics 202 202 242 323 363
Thread Size R₂ 3/4 R₂ 1
Nominal action temperature 68℃ 74℃
Nominal Working Pressure 1.2MPa
Factory test pressure 3.4MPa

Background – History

In the 1980s, early suppression, fast response (ESFR) sprinkler systems were developed as an alternative to in-rack systems. They were designed to actually suppress or extinguish the fire, while conventional sprinklers can only control fires, therefore eliminating the need for extinguishment by firefighters.
How do they work? ESFR sprinklers are designed to release 2-3 times the amount of water of conventional sprinkler heads and to emit larger droplets of water, which in turn have a greater momentum than droplets emitted from conventional heads. As a result, more water and a greater share of the water reaches the fire allowing the flames to be extinguished.

Application

In general, ESFR systems can be used in warehouses with storage that do not exceed 40 feet in overall height, and with a ceiling height of less than 45 feet. And there are sprinkler system protection schemes that will allow storage above those heights. These may include in-rack sprinklers or a combination of ESFR with in-rack sprinklers.
ESFR systems are designed to protect a wide array of commodities. This provides more flexibility in warehouse operations when compared to control mode (conventional) sprinkler systems, which are designed to protect only the commodities that were stored at the time of system installation. If the storage situation requires in-rack sprinklers to be installed to the existing control mode systems of a warehouse building, often building owners prefer to change over to ESFR, simply because then there is no need to worry about damaging in-rack sprinkler heads during normal storage operations. Additionally, in-rack sprinklers have to be removed and sometimes replaced with each new tenant, since the tenants own the racks. Therefore, converting to an ESFR system is at times more cost-effective in the long run.


Product detail pictures:

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures


Related Product Guide:

We insist over the principle of development of 'High top quality, Performance, Sincerity and Down-to-earth working approach' to supply you with exceptional services of processing for Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong , The product will supply to all over the world, such as: Nigeria, Honduras, America, Being the top solutions of our factory, our solutions series have been tested and won us experienced authority certifications. For additional parameters and item list details, be sure to click the button to acquire additional nformation.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Cara from Sacramento - 2018.09.21 11:44
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Austin Helman from Macedonia - 2018.09.12 17:18
    Write your message here and send it to us