With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for Sprinkler Head Hydro, Automatic Fire Sprinklers, Fogger Mister Sprinkler, To supply prospects with superb equipment and providers, and constantly build new machine is our company's organization objectives. We look ahead for your cooperation.
Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong Detail:

Size(mm) Temperature Rating(℃/°F) Color
A 3.8 57℃ / 135°F orange
B 2.02 68℃ / 155°F red
C <4.5 79℃ / 175°F yellow
D 5±0.1 93℃ / 200°F green
d1 5.1±0.2 141℃ / 286°F blue
d2 5.1±0.3
L 19.8±0.5
l1 16±0.4
l2 15.8±0.4
Glass bulb load(N) Average Cursh load(X) 4000
lower Tolerance Limit(TL) ≥2000
Maximum clamping torque 8.0 N·cm
Response time index(m*s)0.5 80<RTI≤350

 

Although it is smaller, each product is subject to strict factory inspection before leaving the factory, including appearance, size, static action temperature and crushing load test.
During the static action temperature test, the test ambient temperature is (20 ± 5) ℃, and the test is carried out in liquid bath. Water bath (distilled water is preferred) shall be adopted for glass bulbs with nominal operating temperature not higher than 79 ℃, and oil bath (oil products suitable for nominal operating temperature) shall be adopted for glass bulbs with nominal operating temperature higher than 79 ℃. The temperature of the test liquid bath shall be uniform, the temperature deviation in the test area shall not exceed 0.5 ℃, and the temperature measurement accuracy shall not be less than ± 0.1 ℃.
Place the glass bulb sample vertically in the liquid bath. The distance between the center of the glass bulb and the liquid level is not less than (40 ± 5) mm. Raise the temperature from room temperature to (20 ± 2) ℃ lower than the nominal operating temperature at a heating rate of not more than 20 ℃ / min. after holding for 10 minutes, raise the temperature at a rate of 0.4 ℃ / min ~ 0.6 ℃ / min until all the samples are broken. Record the operating temperature of each sample, Judge whether the test results exceed the following temperature range:
X ±(0.035X + 0.62)
X — Nominal operating temperature, unit: Celsius (℃).


Product detail pictures:

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures

Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong detail pictures


Related Product Guide:

We keep on with our business spirit of Quality, Performance, Innovation and Integrity. We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for Hot Sale for Brass Bulb Nozzle - Special response sprinkler bulbs (short type) – Zhurong , The product will supply to all over the world, such as: Japan, Cyprus, Portugal, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
  • The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Lulu from Orlando - 2017.07.07 13:00
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Dora from Luxemburg - 2017.01.28 18:53
    Write your message here and send it to us