Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our organization promises all customers with the first-class products and solutions and the most satisfying post-sale service. We warmly welcome our regular and new clients to join us for Fire Sprinkler Wall Spray Head, Fire Sprinklers For Building Projects, Sprinkler Plate, Clients to start with! Whatever you require, we should do our utmost to aid you. We warmly welcome prospects from everywhere in the entire world to cooperate with us for mutual enhancement.
Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong Detail:

Size(mm) Temperature Rating (℃/°F) Color
A 2.4 68℃ / 155°F red
B 1.5 79℃ / 175°F yellow
C <4.2 93℃ / 200°F green
D 3±0.1 141℃ / 286°F blue
d1 3.5±0.4
d2 3.5±0.3
L 23±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 3600
lower Tolerance Limit(TL) ≥1600
aximum clamping torque 6.5 N·cm
Response time index(m*s)0.5 RTI≤50

kjhgoiuhjkl

The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response will be faster, RTI ≤ 50, where RTI is a coefficient measured under standard conditions to measure the sensitivity of sprinkler bulb. Expressions:RTI= τ u ½

Where: RTI – response time coefficient, unit (m * s) ½;
τ- Response time constant, in S;
u – gas flow rate, unit: M / s
The quality of the sprinkler bulb fully complies with the Chinese national standard GB18428-2010. The diameter of the sprinkler bulb is 3mm, and the deviation from the nominal diameter will not exceed ± 0.1mm; Its length is 23mm and the deviation from the nominal length will not exceed 0.5mm.
The average crushing load of the sprinkler bulb is 3600n. During the test, the sprinkler bulb will be fixed between the supporting elements in an appropriate way, and the supporting elements are made of steel. The Rockwell hardness is (44 ± 6) HRC, which meets the corresponding service requirements. Then, apply a uniform load along the axis of the sprinkler bulb until the sprinkler bulb bursts, and the rate of load increase is (250 ± 25) n / s. The maximum deviation of the equipment used to measure the crushing load shall not exceed ± 1% of the measured value. Use multiple groups of measured data to calculate the average value and standard deviation of the crushing load and judge whether the results meet the specified standards.


Product detail pictures:

Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

We have been experienced manufacturer. Wining the majority of your crucial certifications of its market for Short Lead Time for Glass Bulb 68 Degree Fire Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: San Francisco, Mexico, Paraguay, We are seeking the chances to meet all the friends from both at home and abroad for the win-win cooperation. We sincerely hope to have long-term cooperation with all of you on the bases of mutual benefit and common development.
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Jean from Japan - 2017.08.15 12:36
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By olivier musset from Brasilia - 2018.08.12 12:27
    Write your message here and send it to us