Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Quality very first, Honesty as base, Sincere assistance and mutual profit is our idea, in an effort to create consistently and pursue the excellence for Fire Sprinkler Zinc Material, Fire Fighting Sprinklers, Sidewall Fire Sprinkler, We are seeking for extensive cooperation with honest customers, achieving a new cause of glory with customers and strategic partners.
Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong Detail:

Fire Sprinkler
Type Side wall
Material Brass
Nominal diameter(mm) DN15 or DN20
K factor 5.6(80) OR 8.0(115)
Rated Working Pressure 1.2MPa
Testing pressure 3.0MPa holding pressure for 3min
Sprinkler Bulb Fast response
Temperature rating 93℃(200℉)

What is a sidewall sprinkler head?

Sidewall fire sprinklers install along walls or beneath beams where ceiling piping is unavailable, or where aesthetic concerns or obstructions weigh against the use of other sprinkler types. Most are designed to protect small rooms, closets, or hallways and have a semicircular deflector that produces a crescent-shaped spray pattern.
What’s the difference between rated working pressure and testing pressure?
Rated working pressure means pressure under normal conditions.
Testing pressure means pressure for strength test of products.
How to choose the fire sprinkler heads?
The selection and application of sprinkler shall be determined according to the fire risk of the protection place, the building structure of the protection space, the characteristics of the automatic sprinkler system, as well as the flow coefficient, thermal sensitivity index RTI and the maximum protection area of the sprinkler. The fast response sprinkler was first used in residential buildings in the 1970s, and then used in warehouses in the 1980s. Its RTI is less than 50 (m * s)½. The side wall type sprinkler is installed against the wall, which is suitable for installation in places where it is difficult to lay pipes in space. Side wall sprinkler can be used in residential (residential and hotel) and office places with light hazard level and medium hazard level I. Quick response sprinklers should be used in medium and light hazard places and places for life protection, such as public entertainment places, houses, atrium corridors, hospitals, wards and treatment areas of nursing homes, collective activity places for the elderly, children and the disabled, etc. According to the specification, the maximum temperature at the general installation site is 30 ℃ + 30 ℃. Some special places with temperature such as kitchen and boiler room need to use 93℃ (200℉) sprinkler heads.


Product detail pictures:

Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong detail pictures

Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong detail pictures

Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong detail pictures


Related Product Guide:

Our products are broadly regarded and reliable by end users and can meet up with constantly transforming financial and social requires of Upright Fire Hoses ZSTX 15-93℃ Side wall Chrome plated Fast response Fire sprinkler heads – Zhurong , The product will supply to all over the world, such as: Cairo, Belgium, Kyrgyzstan, We've got a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will absolutely benefit in both short and long run.
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Pag from Colombia - 2017.09.28 18:29
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Edwina from Tajikistan - 2018.02.04 14:13
    Write your message here and send it to us