              Sidewall Sprinkler Head For Wall Mounted Fire ProtectionParameters and Functions Model & Sprinkler I.D. No. NX021 Style Horizontal Sidewall Response & Bulb Nominal Dia. Standard Response, Ø5 mm Thread Size [Optional] NPT1/2 or R1/2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 1 5.6 (U.S.)/80 (metric) Max. Working Pressure 175 psig/1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig/0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated Whit...
- 
              Wide range of water curtain nozzle of high qualityWater Curtain Nozzle Sprinkler head type open Fire Sprinkler Type Drench Nozzle,water curtain Application Firefighting, fire water system,deluge valve system Material Brass/Stainless Steel Working Pressure 0.35MPa Model No. ZSTM Port Ningbo,China Transport Package Standard Export Carton Water curtain show Angle 45°,60°,90°,120°,150° Working principle The water curtain sprinkler is a type of open sprinkler with only one outletUnder.The action of pressure water, the wa...
- 
              Concealed Fire sprinkler MH-ZSTDY 1/2”Concealed sprinkler is applicable to places with luxurious decoration and beautiful appearance requirements, such as shopping malls, high-end hotels, hotels, entertainment centers, etc. It is also applicable to places where the ceiling is too low and the clearance is limited due to decoration, air conditioning and other factors, as well as places where people are crowded, goods are handled frequently, and exposed sprinklers can be collided at any time to avoid accidental action caused by huma...
- 
              Conceal Type Automatic Fire SprinklerResponse special/quick K-factor 5.6(80.6)/8.0(115.2) Installation type pendent Glass ball diameter 3mm/5mm Place of origin Zhejiang, China construction The concealed sprinkler is composed of glass bulb sprinkler, screw sleeve seat, outer cover seat and outer cover. The sprinkler and screw socket are installed on the pipeline of the pipe network together, and then the cover is installed. installation environment Concealed fire sprinkler is suitable to be installed in places with ...
- 
              5mm Special response sprinkler bulbsA glass sprinkler bulb is the most reliable and economic device used to actuate a fire sprinkler head. The frangible bulb is simple to use, comprising a small thermo bulb made of glass containing a chemical liquid that will expand rapidly when exposed to rising temperatures, bursting the glass fire bulb at an accurately pre-determined temperature, thereby activating the sprinkler. Size(mm) Temperature Rating(℃/°F) Color A 3.8 57℃ / 135°F orange B 2.02 68℃ / 155°...
- 
              DN15 brass fire sprinkler is directly manufactured in the factoryFire Sprinkler Type Pendent Material Brass Nominal diameter(mm) DN15 or DN20 K factor 5.6(80) OR 8.0(115) Rated Working Pressure 1.2MPa Testing pressure 3.0MPa holding pressure for 3min Sprinkler Bulb Special response Temperature rating 68℃(155℉) MOQ 200PCS Sprinkler for extinguishing fire according to fire signal Fire sprinkler: a sprinkler that starts automatically according to the predetermined temperature range under the action of heat, or starts by the control ...
- 
              New Arrival Standard Coverage Pendent Concealed Fire SprinklersSpecification Model ZSTDY Response Special Style Pendent Nominal diameter DN15/DN20 Glass bulb diameter 3mm/5mm Material Brass Concealed sprinkler Temperature rating Max applicable ambient temperature Falling off temperature of cover plate 68.3℃ 38℃ 57.2℃ 79.4℃ 49℃ 73.8℃ 93.3℃ 63℃ 73.8℃ The fire sprinkler head is used in the fire sprinkler system. When a fire occurs, water is spilled through the spray head splash tray to extinguish the fire. Common spray he...
- 
              fire sprinkler head pendent sprinkler upright sprinkler sidewall sprinkler manufacture OEMFire Sprinkler Material Brass Nominal diameter(mm) DN15 or DN20 K factor 5.6(80) OR 8.0(115) Rated Working Pressure 1.2MPa Testing pressure 3.0MPa holding pressure for 3min Sprinkler Bulb Special response Temperature rating 57℃、68℃、79℃、93℃、141℃ Ningbo MenHai Fire Equipment Manufacturing Co., Ltd. is an independent manufacturer of fire sprinklers, sprinkler bulbs, plastic accessories and hardware accessories. With our excellent independent ability, we control and adju...
- 
              MH-ZSTGX80 68℃ Q5 / Q3 Dry type pendent fire sprinkler K factor 5.61. Description Ningbo Menhai Fire Equipment Manufacturing Co., Ltd., as a professional manufacturer of fire sprinkler, supports the customization of all parts of the product. The dry fire sprinkler is applicable to cold areas, and its length varies with the needs of the use scenario. The dry type fire sprinkler head is designed with stainless steel internals, and is mainly used in dry or pre action systems, as well as in places where the fire sprinkler head or some of its nozzles need to be e...
- 
              Factory Direct Supply with Thermo Bulbs Pendent Fire SprinklerFire sprinkler Details Material brass Norminal Diameter DN15,DN20 Model No. T-ZSTZ15-57℃ 68℃ 79℃ 93℃ 141℃ Glass bulb 3mm/5mm Place of Origin Ningbo,China Response special Packing In carton K factor 5.6(80) / 8.0(115) Installation type Pendent MOQ 200pcs Glass ball is a kind of temperature sensing element, which is equipped with a certain amount of heat-sensitive expansion liquid, different liquid colors distinguish different nominal operating temperature, when th...
- 
              Factory directly produces fire sprinkler1.Sprinkler The fire sprinkler head is used for the fire sprinkler system. In case of fire, water is sprinkled through the sprinkler head splash tray to extinguish the fire. It is divided into drooping sprinkler head, vertical sprinkler head, ordinary sprinkler head, side wall sprinkler head, etc. Sprinkler is a kind of sprinkler that starts automatically within the predetermined temperature range under the action of heat, or starts by the control equipment according to the fire signal, and...
- 
              Customized dry pendent sprinkler Directly supplied by the fire sprinkler manufactureModel T-ZSTGX 80-68℃ Q5 T-ZSTGX 80-93℃ Q5 T-ZSTGX 80-68℃ Q3 T-ZSTGX 80-93℃ Q3 Mounting Pendent Thread Size R₂ 1 Nominal Working Pressure 1.2MPa Factory test pressure 3.0MPa Flow characteristics 80 Mounting dimensions Customized 75-1400mm according to customer requirements Thermal dynamic properties 50~80(m.s)½ ≤50(m.s)½ The dry sprinkler head is a kind of ordinary drooping sprinkler head specially used for dry system. The most commonly used sprin...